Building fire safety systems
(136)
Fire safety. Find the best solution for your project here.
Building fire safety systems - helping you find the best solution for your project.
Conventional sounders and strobes range
Visit site
Conventional sounders and sounder/strobes are suitable for both fire and security applications and are available in 4 and 14 tone versions. Low-profile, surface and waterproof versions are available, enabling the units to be used internally or externally. Detector base sounders and strobes are also available for use underneath smoke detectors or- PRODUCT
- KAC Alarm Company
Discovery isolating base
Visit siteDiscovery intelligent mounting base
Visit site
The Discovery intelligent mounting base requires only a low insertion force for installation, making it suitable for use on suspended ceilings. It has stainless steel contacts for the detector terminals and is supplied with an XPERT card. All detectors in the Discovery and XP95 ranges fit into the intelligent mounting base- PRODUCT
- Apollo Fire Detectors
AlarmSense manual call point
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The AlarmSense manual call point is compliant with EN54:11. It is different from other conventional call points in that it can be detected as an operated call point rather than a detector that has changed to the
XPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander multisensor detector containsInterfaces input/output unit
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The input/output unit provides a voltage-free, single-pole, change-over relay output, a single monitored switch input and an unmonitored- PRODUCT
- Apollo Fire Detectors
Discovery multisensor detector
Visit siteSeries 65 standard relay base
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 standard relay base provides one set of volt-free changeover (from C) contacts that change state when the detector signals an alarm. Features: Advanced electronic technology- PRODUCT
- Apollo Fire Detectors
XPander heat detector and mounting base
Visit site
XPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander rate-of-rise heat detectorXP95 ionisation smoke detector
Visit site
The XP95 ionisation smoke detector uses irradiated air in the dual sensing chambers to produce ions that travel to the positive and negative electrodes, creating a current flow. As smoke enters the outer chamber, the flow drops and voltage increases. The voltage is measured and an analogue signal is converted to digital for transmission to theSeries 65 ionisation smoke detector
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The ionisation smoke detector irradiates air in the dual sensing chambers to produce ions that travel to the positive and negative electrodes, creating a current flow. As smoke enters theDiscovery carbon monoxide detector
Visit site
The Discovery carbon monoxide (CO) fire detector contains a long-life electrochemical CO sensor. The sensing technology is fast, accurate and needs only very low power. It does not detect smoke particles or heat and are is not a universal replacement for smoke detectors. CO fire detectors are electronic detectors that can indicate the outbreak ofInterfaces DIN-Rail switch monitor
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The switch monitor is designed to monitor the state of one or more single-pole, volt-free contacts and report the status to Apollo compatibleIntelligent audible visual alarms
Visit site
KACs analogue addressable range of audible visual alarms has been designed to meet the requirements of modern intelligent fire systems. The alarms can be installed as traditional wall-mounted devices or as detector base devices. A separate, common installation base is installed to allow simple twist fit of the AV device. This has a shorting spring- PRODUCT
- KAC Alarm Company
Discovery heat detector
Visit siteXPander red sounder beacon and base
Visit site
XPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander sounder beacon and sounderInterfaces DIN-Rail zone monitor
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-Rail Zone Monitor with Isolator controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery orAlarmSense sounder base
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The AlarmSense sounder base is fitted with electronic circuitry to monitor the presence of detectors and signals any unauthorised removal of detector heads. It is supplied with a high or low volume setting and- PRODUCT
- Apollo Fire Detectors
WCP outdoor manual call points
Visit site
WCP outdoor call points are designed for use in extreme weather conditions, with an operating temperature range of -30°C to +70°C. WCP models are available with configurations compatible with all conventional panels and intelligent versions are offered to meet specific requirements. The WCP range is approved to EN 54-11: most products are offered- PRODUCT
- KAC Alarm Company
XP95 multisensor detector
Visit siteAlarmSense optical smoke detector
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The optical smoke detector uses an internal pulsing LED and a photodiode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered and registered by the
XPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander optical smoke detector worksAlarmSense heat detector
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The AlarmSense heat detector operates by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature, the other is sealed. In normal conditions, the two thermistorsSeries 65 A1R heat detector
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The A1R heat detector operates by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature, the other is sealed. In normal conditions, the two

Sign up to receive the free BUILDING SERVICES bulletin
By signing up, you agree to our Terms and Conditions and Privacy Policy.
We won’t share your email address with anyone without your consent. Bulletins are sent on a weekly basis. You can unsubscribe anytime.