Refine by
Channel
Showing best results - all illustrated entries. Change the channel to view specific categories.
Building fire protection
(123)
Building fire protection. Find the best solution for your project here.
Building fire protection - helping you find the best solution for your project.
Interfaces DIN-Rail output unit
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-Rail input/output unit provides a voltage-free, single-pole, change-over relay output, a single monitored switch input and an unmonitoredXPander red sounder beacon and base
Visit site
XPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander sounder beacon and sounderInterfaces DIN-Rail input/output unit
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-rail output unit provides a voltage-free single-pole, change-over relay output. It is a simplified version of the input/output unit withoutAlarmSense optical smoke detector
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The optical smoke detector uses an internal pulsing LED and a photodiode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered and registered by the- PRODUCT
- Apollo Fire Detectors
Interfaces zone monitor
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The zone monitor powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 loopSeries 65 standard mounting base
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 standard mounting base has been designed to enable detectors to be fitted without the need of force. It is particularly useful when fitting to suspended ceilings. All Series 65- PRODUCT
- Apollo Fire Detectors
AlarmSense heat detector
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The AlarmSense heat detector operates by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature, the other is sealed. In normal conditions, the two thermistors- PRODUCT
- Apollo Fire Detectors
Series 65 ionisation smoke detector
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The ionisation smoke detector irradiates air in the dual sensing chambers to produce ions that travel to the positive and negative electrodes, creating a current flow. As smoke enters the- PRODUCT
- Apollo Fire Detectors
WCP outdoor manual call points
Visit site
WCP outdoor call points are designed for use in extreme weather conditions, with an operating temperature range of -30°C to +70°C. WCP models are available with configurations compatible with all conventional panels and intelligent versions are offered to meet specific requirements. The WCP range is approved to EN 54-11: most products are offered- PRODUCT
- KAC Alarm Company
AlarmSense alarm relay
Visit site
The AlarmSense range of conventional detection and alarm products is specially designed to be connected to the same pair of supply wires. The AlarmSense alarm relay enables devices such as beacons, pillow/bed alarms and radio vibrating or paging devices to be connected to the fire detection system. This can help systems comply with theXPander sounder and sounder base
Visit site
XPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander sounder and sounder base is a- PRODUCT
- Apollo Fire Detectors
Series 65 diode base
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 diode base is designed for use with conventional systems that have manual call points and detector bases on the same circuit. The base is fitted with a schottky diode on both the- PRODUCT
- Apollo Fire Detectors
AlarmSense sounder beacon base
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. Providing an alarm between 70 and 87dB(A), the AlarmSense sounder beacon base will detect the removal of a detector head and report a fault. It continues to work during unauthorised removal of detectors. Quick and- PRODUCT
- Apollo Fire Detectors
MCP indoor manual call points range
Visit site
KAC offers a large range of call points which can be conventional or analogue addressable and surface or flush-mounted. The MCP range is designed to reduce installation time, by using a special terminal block connected to the back of the call point, where all initial installation cabling is terminated. MCP call points can be configured as either- PRODUCT
- KAC Alarm Company
Discovery isolating base
Visit site
The Discovery isolating base senses and detects short-circuit faults on Discovery and XP95 loops and spurs- PRODUCT
- Apollo Fire Detectors
XPander manual call point
Visit site
XPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander Manual Call Point is compliant- PRODUCT
- Apollo Fire Detectors
AlarmSense sounder base
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The AlarmSense sounder base is fitted with electronic circuitry to monitor the presence of detectors and signals any unauthorised removal of detector heads. It is supplied with a high or low volume setting and- PRODUCT
- Apollo Fire Detectors
Interfaces sounder control unit
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The sounder control unit is used to control the operation of a zone of conventional sounders and report their status to the control panel. The unitSeries 65 end-of-line relay base
Visit siteThe Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 end-of-line (EOL) relay base is intended for use with four-wire circuits. It features two sets of changeover contacts and a power supervision relay. Features: Advanced electronic- PRODUCT
- Apollo Fire Detectors
Interfaces DIN-Rail zone monitor
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-Rail Zone Monitor with Isolator controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery orXP95 heat detector
Visit site
The XP95 heat detector has a low air-flow resistant case for good contact between the sensing thermistor and the surrounding air. Temperature is measured by a single thermistor network which gives a voltage output proportional to the external air temperature. The signal is processed and transmitted to the control equipment- PRODUCT
- Apollo Fire Detectors
Series 65 auxiliary relay base
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 auxiliary relay base provides two sets of volt-free changeover contacts to facilitate the switching of a remote LED or other auxiliary device. Features: Advanced electronic- PRODUCT
- Apollo Fire Detectors
Series 65 standard relay base
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 standard relay base provides one set of volt-free changeover (from C) contacts that change state when the detector signals an alarm. Features: Advanced electronic technology- PRODUCT
- Apollo Fire Detectors

Sign up to receive the free BUILDING SERVICES bulletin
By signing up, you agree to our Terms and Conditions and Privacy Policy.
We won't share your email address with anyone without your consent. Bulletins are sent on a weekly basis. You can unsubscribe anytime.
