Refine by
Channel
Showing best results - all illustrated entries. Change the channel to view specific categories.
Building fire protection
(120)
Building fire protection. Find the best solution for your project here.
Building fire protection - helping you find the best solution for your project.
WCP outdoor manual call points
Visit site
WCP outdoor call points are designed for use in extreme weather conditions, with an operating temperature range of -30°C to +70°C. WCP models are available with configurations compatible with all conventional panels and intelligent versions are offered to meet specific requirements. The WCP range is approved to EN 54-11: most products are offered- PRODUCT
- KAC Alarm Company
MCP indoor manual call points range
Visit site
KAC offers a large range of call points which can be conventional or analogue addressable and surface or flush-mounted. The MCP range is designed to reduce installation time, by using a special terminal block connected to the back of the call point, where all initial installation cabling is terminated. MCP call points can be configured as either- PRODUCT
- KAC Alarm Company
AlarmSense sounder base
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The AlarmSense sounder base is fitted with electronic circuitry to monitor the presence of detectors and signals any unauthorised removal of detector heads. It is supplied with a high or low volume setting and- PRODUCT
- Apollo Fire Detectors
Series 65 auxiliary relay base
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 auxiliary relay base provides two sets of volt-free changeover contacts to facilitate the switching of a remote LED or other auxiliary device. Features: Advanced electronic- PRODUCT
- Apollo Fire Detectors
Interfaces mini switch monitor
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The switch monitor from the Miniature range is designed to monitor the state of one or more single-pole, volt-free contacts connected on a singleDiscovery carbon monoxide detector
Visit site
The Discovery carbon monoxide (CO) fire detector contains a long-life electrochemical CO sensor. The sensing technology is fast, accurate and needs only very low power. It does not detect smoke particles or heat and are is not a universal replacement for smoke detectors. CO fire detectors are electronic detectors that can indicate the outbreak of- PRODUCT
- Apollo Fire Detectors
Discovery intelligent mounting base
Visit site
The Discovery intelligent mounting base requires only a low insertion force for installation, making it suitable for use on suspended ceilings. It has stainless steel contacts for the detector terminals and is supplied with an XPERT card. All detectors in the Discovery and XP95 ranges fit into the intelligent mounting base- PRODUCT
- Apollo Fire Detectors
XP95 heat detector
Visit site
The XP95 heat detector has a low air-flow resistant case for good contact between the sensing thermistor and the surrounding air. Temperature is measured by a single thermistor network which gives a voltage output proportional to the external air temperature. The signal is processed and transmitted to the control equipment- PRODUCT
- Apollo Fire Detectors
Intelligent audible visual alarms
Visit site
KACs analogue addressable range of audible visual alarms has been designed to meet the requirements of modern intelligent fire systems. The alarms can be installed as traditional wall-mounted devices or as detector base devices. A separate, common installation base is installed to allow simple twist fit of the AV device. This has a shorting spring- PRODUCT
- KAC Alarm Company
Interfaces zone monitor
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The zone monitor powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 loopInterfaces DIN-Rail output unit
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-Rail input/output unit provides a voltage-free, single-pole, change-over relay output, a single monitored switch input and an unmonitoredAlarmSense heat detector
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The AlarmSense heat detector operates by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature, the other is sealed. In normal conditions, the two thermistors- PRODUCT
- Apollo Fire Detectors
AlarmSense mounting base
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. AlarmSense mounting bases are specifically designed for the mounting of AlarmSense detectors. They are fitted with electronic circuitry to monitor the presence of detectors and allow a fault to be signalled if a- PRODUCT
- Apollo Fire Detectors
Interfaces DIN-Rail zone monitor
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-Rail Zone Monitor with Isolator controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery orInterfaces DIN-Rail input/output unit
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-rail output unit provides a voltage-free single-pole, change-over relay output. It is a simplified version of the input/output unit withoutXP95 ionisation smoke detector
Visit site
The XP95 ionisation smoke detector uses irradiated air in the dual sensing chambers to produce ions that travel to the positive and negative electrodes, creating a current flow. As smoke enters the outer chamber, the flow drops and voltage increases. The voltage is measured and an analogue signal is converted to digital for transmission to the- PRODUCT
- Apollo Fire Detectors
Discovery heat detector
Visit site
The Discovery heat detector, distinguishable by a low airflow resistant case, uses a single thermistor to sense the air temperature around the detector. The thermistor is connected in a resistor network, which produces a voltage output dependent on temperature- PRODUCT
- Apollo Fire Detectors
XPander manual call point
Visit site
XPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander Manual Call Point is compliant- PRODUCT
- Apollo Fire Detectors
XPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander optical smoke detector worksAlarmSense alarm relay
Visit site
The AlarmSense range of conventional detection and alarm products is specially designed to be connected to the same pair of supply wires. The AlarmSense alarm relay enables devices such as beacons, pillow/bed alarms and radio vibrating or paging devices to be connected to the fire detection system. This can help systems comply with theSeries 65 ionisation smoke detector
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The ionisation smoke detector irradiates air in the dual sensing chambers to produce ions that travel to the positive and negative electrodes, creating a current flow. As smoke enters the- PRODUCT
- Apollo Fire Detectors
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The integrating optical smoke detector uses an internal pulsing LED and a photodiode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered and registered byXP95 optical smoke detector
Visit site
The XP95 optical detector uses an internal pulsing LED and a photo-diode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered and registered by the photo-diode. A signal is generated and transmitted digitally to the control equipment- PRODUCT
- Apollo Fire Detectors

Sign up to receive the free BUILDING SERVICES bulletin
By signing up, you agree to our Terms and Conditions and Privacy Policy.
We won’t share your email address with anyone without your consent. Bulletins are sent on a weekly basis. You can unsubscribe anytime.