Series 65 A1R heat detector
Visit siteThe Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The A1R heat detector operates by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature, the other is sealed. In normal conditions, the twoWCP outdoor manual call points
Visit siteWCP outdoor call points are designed for use in extreme weather conditions, with an operating temperature range of -30°C to +70°C. WCP models are available with configurations compatible with all conventional panels and intelligent versions are offered to meet specific requirements. The WCP range is approved to EN 54-11: most products are offered- PRODUCT
- KAC Alarm Company
XP95 ionisation smoke detector
Visit siteThe XP95 ionisation smoke detector uses irradiated air in the dual sensing chambers to produce ions that travel to the positive and negative electrodes, creating a current flow. As smoke enters the outer chamber, the flow drops and voltage increases. The voltage is measured and an analogue signal is converted to digital for transmission to theInterfaces DIN-Rail zone monitor
Visit siteApollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-Rail Zone Monitor with Isolator controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery orInterfaces three-channel input/output unit
Visit siteApollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The three-channel input/output unit provides three voltage-free, single pole, changeover relay outputs and three monitored switch inputs. The unitAlarmSense alarm relay
Visit siteThe AlarmSense range of conventional detection and alarm products is specially designed to be connected to the same pair of supply wires. The AlarmSense alarm relay enables devices such as beacons, pillow/bed alarms and radio vibrating or paging devices to be connected to the fire detection system. This can help systems comply with theInterfaces zone monitor
Visit siteApollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The zone monitor powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 loopXPander heat detector and mounting base
Visit siteXPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander rate-of-rise heat detectorAlarmSense sounder beacon base
Visit siteAlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. Providing an alarm between 70 and 87dB(A), the AlarmSense sounder beacon base will detect the removal of a detector head and report a fault. It continues to work during unauthorised removal of detectors. Quick and- PRODUCT
- Apollo Fire Detectors
Interfaces mini switch monitor
Visit siteApollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The switch monitor from the Miniature range is designed to monitor the state of one or more single-pole, volt-free contacts connected on a singleXP95 heat detector
Visit siteThe XP95 heat detector has a low air-flow resistant case for good contact between the sensing thermistor and the surrounding air. Temperature is measured by a single thermistor network which gives a voltage output proportional to the external air temperature. The signal is processed and transmitted to the control equipmentDiscovery multisensor detector
Visit siteXPander manual call point
Visit siteXPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander Manual Call Point is compliantSeries 65 standard relay base
Visit siteThe Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 standard relay base provides one set of volt-free changeover (from C) contacts that change state when the detector signals an alarm. Features: Advanced electronic technology- PRODUCT
- Apollo Fire Detectors
AlarmSense manual call point
Visit siteAlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The AlarmSense manual call point is compliant with EN54:11. It is different from other conventional call points in that it can be detected as an operated call point rather than a detector that has changed to theSeries 65 optical smoke detector
Visit siteThe Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The optical smoke detector uses an internal pulsing LED and a photodiode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered andXP95 optical smoke detector
Visit siteThe XP95 optical detector uses an internal pulsing LED and a photo-diode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered and registered by the photo-diode. A signal is generated and transmitted digitally to the control equipment- PRODUCT
- Apollo Fire Detectors
Discovery optical smoke detector
Visit siteThe Discovery optical smoke detector uses an IR LED that pulses light across a smoke chamber with a photodiode set at an obtuse angle. In clear air it receives no light, but when smoke enters the chamber, light from the LED is scattered onto the photodiode. A signal is then processed to provide an analogue value for transmission when the detectorInterfaces DIN-Rail input/output unit
Visit siteApollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-rail output unit provides a voltage-free single-pole, change-over relay output. It is a simplified version of the input/output unit withoutDiscovery isolating base
Visit siteInterfaces DIN-Rail output unit
Visit siteApollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-Rail input/output unit provides a voltage-free, single-pole, change-over relay output, a single monitored switch input and an unmonitoredInterfaces DIN-Rail switch monitor
Visit siteApollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The switch monitor is designed to monitor the state of one or more single-pole, volt-free contacts and report the status to Apollo compatibleDiscovery heat detector