Refine by
Channel
Showing best results - all illustrated entries. Change the channel to view specific categories.
Building fire safety systems
(136)
Fire safety. Find the best solution for your project here.
Building fire safety systems - helping you find the best solution for your project.
Series 65 auxiliary relay base
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 auxiliary relay base provides two sets of volt-free changeover contacts to facilitate the switching of a remote LED or other auxiliary device. Features: Advanced electronicSeries 65 standard mounting base
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 standard mounting base has been designed to enable detectors to be fitted without the need of force. It is particularly useful when fitting to suspended ceilings. All Series 65- PRODUCT
- Apollo Fire Detectors
Interfaces DIN-Rail output unit
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-Rail input/output unit provides a voltage-free, single-pole, change-over relay output, a single monitored switch input and an unmonitoredInterfaces DIN-Rail zone monitor
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-Rail Zone Monitor with Isolator controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery orSeries 65 optical smoke detector
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The optical smoke detector uses an internal pulsing LED and a photodiode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered andInterfaces mini switch monitor
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The switch monitor from the Miniature range is designed to monitor the state of one or more single-pole, volt-free contacts connected on a singleInterfaces sounder control unit
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The sounder control unit is used to control the operation of a zone of conventional sounders and report their status to the control panel. The unitSeries 65 A1R heat detector
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The A1R heat detector operates by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature, the other is sealed. In normal conditions, the twoSeries 65 standard relay base
Visit site
The Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 standard relay base provides one set of volt-free changeover (from C) contacts that change state when the detector signals an alarm. Features: Advanced electronic technology- PRODUCT
- Apollo Fire Detectors
Interfaces DIN-Rail switch monitor
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The switch monitor is designed to monitor the state of one or more single-pole, volt-free contacts and report the status to Apollo compatibleInterfaces input/output unit
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The input/output unit provides a voltage-free, single-pole, change-over relay output, a single monitored switch input and an unmonitored- PRODUCT
- Apollo Fire Detectors
AlarmSense heat detector
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The AlarmSense heat detector operates by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature, the other is sealed. In normal conditions, the two thermistorsIntelligent audible visual alarms
Visit site
KACs analogue addressable range of audible visual alarms has been designed to meet the requirements of modern intelligent fire systems. The alarms can be installed as traditional wall-mounted devices or as detector base devices. A separate, common installation base is installed to allow simple twist fit of the AV device. This has a shorting spring- PRODUCT
- KAC Alarm Company
Explosion suppression systems
Visit site
FM and ATEX approved chemical suppression systems operate within milliseconds to suppress an explosion before any damage is caused to plant or personnel are harmed. They are designed for process industry applications involving flammable dusts or powders, and in which there is potential for expensive or hazardous explosions in cyclones, filters- PRODUCT
- Fike United Kingdom
AlarmSense alarm relay
Visit site
The AlarmSense range of conventional detection and alarm products is specially designed to be connected to the same pair of supply wires. The AlarmSense alarm relay enables devices such as beacons, pillow/bed alarms and radio vibrating or paging devices to be connected to the fire detection system. This can help systems comply with theAlarmSense manual call point
Visit site
AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The AlarmSense manual call point is compliant with EN54:11. It is different from other conventional call points in that it can be detected as an operated call point rather than a detector that has changed to theDiscovery intelligent mounting base
Visit site
The Discovery intelligent mounting base requires only a low insertion force for installation, making it suitable for use on suspended ceilings. It has stainless steel contacts for the detector terminals and is supplied with an XPERT card. All detectors in the Discovery and XP95 ranges fit into the intelligent mounting base- PRODUCT
- Apollo Fire Detectors
Interfaces zone monitor
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The zone monitor powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 loopDiscovery multisensor detector
Visit siteXP95 ionisation smoke detector
Visit site
The XP95 ionisation smoke detector uses irradiated air in the dual sensing chambers to produce ions that travel to the positive and negative electrodes, creating a current flow. As smoke enters the outer chamber, the flow drops and voltage increases. The voltage is measured and an analogue signal is converted to digital for transmission to theInterfaces DIN-Rail input/output unit
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-rail output unit provides a voltage-free single-pole, change-over relay output. It is a simplified version of the input/output unit withoutInterfaces three-channel input/output unit
Visit site
Apollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The three-channel input/output unit provides three voltage-free, single pole, changeover relay outputs and three monitored switch inputs. The unitWCP outdoor manual call points
Visit site
WCP outdoor call points are designed for use in extreme weather conditions, with an operating temperature range of -30°C to +70°C. WCP models are available with configurations compatible with all conventional panels and intelligent versions are offered to meet specific requirements. The WCP range is approved to EN 54-11: most products are offered- PRODUCT
- KAC Alarm Company
Conventional sounders and strobes range
Visit site
Conventional sounders and sounder/strobes are suitable for both fire and security applications and are available in 4 and 14 tone versions. Low-profile, surface and waterproof versions are available, enabling the units to be used internally or externally. Detector base sounders and strobes are also available for use underneath smoke detectors or- PRODUCT
- KAC Alarm Company

Sign up to receive the free BUILDING SERVICES bulletin
By signing up, you agree to our Terms and Conditions and Privacy Policy.
We won’t share your email address with anyone without your consent. Bulletins are sent on a weekly basis. You can unsubscribe anytime.
