Smoke dampers
Smoke dampers - helping you find the best solution for your project.
SG-BV60 fireproof intumescent grille
Visit siteThe fire-rated intumescent grille is designed for use as a fire barrier in either doors or partitions and has a 1 hour fire rating in accordance with BS 476 Part 8 "Test methods and criteria for the fire resistance of elements of building construction". The core of the grille comprises a lattice of Palusol 210 intumescent material which swells atFKA2-EU rectangular fire damper
Visit siteType EK2-EU - smoke control damper
Visit siteRectangular smoke control dampers with extract ventilation function, for smoke extract with mechanical smoke extract systems or as an additional supply air inlet. Smoke control dampers of Type EK-EU, with CE marking and declaration of performance, for smoke extract with mechanical smoke extract systems; also for natural smoke and heat exhaust systemsType JF - Tunnel Damper
Visit siteTROX tunnel dampers of Type JF are specially designed safety components that meet the RABT and RVS requirements; for opening and closing smoke extract ducts; used in ventilation and smoke extract systems in underground transport systems; can also be used as shut-off dampers for fans; installation usually either above the roadway in an intermediateType EK-JZ - Smoke Control Damper
Visit sitesmoke control damper of Type EK-JZ, with CE marking and declaration of performance, for heat and smoke exhaust with mechanical smoke extract systems; for the provision of fresh air (additional supply air) to mechanical smoke extract systems; in pressurisation systems; can be used for ventilation if the mechanical smoke extract system has been
Smoke dampers - helping you find the best companies for your project.
Advanced Air
Advanced Air (UK) Ltd, Burrell Way, Thetford, IP24 3WBAutomated Control Services
Supplies and installs automatic opening ventilation systems which react immediately to the detection of smoke, venting toxic fumes from escape routes and stairwells. All systems are provided with an emergency battery back up system as standard, so that smoke control will still function in the event of a power failure
Unit 16, Hightown Industrial Estate, Crow Arch Lane, Ringwood, BH24 1NDBSB Engineering Services
Manufactures air, fire and smoke control dampers that are tested and conform to national and international specifications
Unit E, Tribune Drive, Trinity Trading Estate, Sittingbourne, ME10 2PDGilberts (Blackpool)
Manufactures a curtain-type fire damper designed to stop the spread of flames through ductwork. Fitted where the ductwork passes through an existing barrier, the damper is activated by a fusible link element set to trigger at 72°C. Operation of the link immediately shuts the steel blades under spring tension, thus providing a solid fire barrier
Clifton Road, Blackpool, FY4 4QTHalton Products
Halton ventilation fire safety systems include fire dampers, smoke and smoke evacuation dampers and fire valves. The Technical Research Centre of Finland (VTT) is in charge of the fire dampers quality control. In addition, all Halton fire dampers are tested prior to their delivery to customers
4 The Matchyns, London Road, Rivenhall, Witham, CM8 3HAHotchkiss Air Supply
Offers curtain-bladed fire dampers to stop the spread of flame through ducts, walls, floors and ceilings. Standard dampers have a two-hour fire rating and are made from galvanised mild steel. Blades can be manufactured from stainless steel, if required. The dampers are suitable for installation in rectangular, circular and flat oval ducting
Heath Mill Road, Wombourne, Wolverhampton, WV5 8APLorient Polyproducts
Manufactures high performance intumescent dampers with no moving parts. They form a seal in two minutes and can withstand a 300Pa pressure differential across the damper. Fire integrity is maintained for four hours
Endeavour House, Fairfax Road, Heathfield Industrial Estate, Newton Abbot, TQ12 6UDParking Ventilation Equipment Ltd
The HC-PVE range of extract dampers provide automatic shut off of airflow in ducts and voids in the case of fire. They have been fire rated to BS 475-8 by the Fire Insurers Research and Testing Organisation. There was no loss of structural integrity even after a 2-hour heating period
Unit 5, Prince of Wales Mill, Birds Royd Lane, Brighouse, HD6 1LQSE Controls
Manufactures, installs and maintains natural and smoke ventilation systems for public and commercial buildings. Motorised, pneumatic and magnetic opening systems can be employed to open vents, which can be both vertical and roof-fitted. Control panels for the systems can be designed to meet specific requirements for individual buildings. Contracts
Lancaster House, Wellington Crescent, Fradley Park, Lichfield, WS13 8RZSmoke Control Services
Supplier and installer of natural and mechanical smoke ventilators and control systems. Louvred ventilators are designed to facilitate the removal of large quantities of smoke or warm air into rooftop areas. Panels are made from corrosion resistant aluminium, glass or translucent polycarbonate, and can be installed in tiled or slated roofs
The Innovation Centre, Tredomen Business Park, Hengoed, CF82 7FN